TM9-2350-311-20-1
b.
c.
d.
4
Disconnect connector (5) at air cleaner blower motor lead wire 415 (9).
5 Remove five screws (10), five Iockwashers (11), five washers (12), and five straps (13). Remove wiring
harness (14). Discard Iockwashers.
Disassembly/Repair
Disassemble (para 2-13).
Assembly
Assemble (para 2-13).
Installation
1 Install connector (5) at air cleaner blower motor lead wire 415 (9).
2 Install two connectors (3 and 4) at neutral safety switch (8).
3 Install connector (2) wire 415 at circuit breaker (7).
4 Install connector (1) at air cleaner blower motor relay (6).
5 Install wiring harness (14), five straps (13), five washers (12), five new Iockwashers (11), and five screws (10).
FOLLOW-ON MAINTENANCE:
NOTE
Connect batteries (para 8-28)
Install portable instrument panel (8-17)
8-181