TM 9-2350-311-20-1
8-70 FLAME HEATER SWITCH LEAD (ENGINE MODEL 7083-7396) — CONTINUED
a. Removal
1 Disconnect connector (1) at flame heater switch.
2 Disconnect two connectors (2 and 3) at wires 486A and 486.
b. Installation
1 Connect two connectors (2 and 3) at wires 486A and 486.
2 Connect connector (1) at flame heater switch.
NOTE
FOLLOW-ON MAINTENANCE:
Connect batteries (para 8-28)
Install portable instrument panel (para 8-17)
8-71 CIRCUIT BREAKER-TO-”Y” CONNECTOR LEAD
This task covers:
a. Removal
b. Installation
Batteries disconnected (para 8-28)
Portable instrument panel removed (para 8-17)
8-178