5-5 AIR CLEANER BLOWER MOTORS — CONTINUED
a. Disassembly
1
2
3
4
5
Remove 10 screws (1), 10 Iockwasher (2), and motor cover (3). Discard Iockwasher.
Slide electrical lead insulator (4) away from connector (5).
Disconnect electrical lead (6) at connector (5).
Remove screw (7) and disconnect ground lead (8). Install screw to commutator end bell (9).
Remove motor assembly (10) and two seals (11). Discard seals.