TM9-2350-311-34-1
11 Connect shielded electrical cable (4) to cover assembly (5) and install at fuel pump (6).
NOTE
Elbow connector is on left fuel pump only.
12 Install elbow connector (2) and check valve (1) at discharge fitting (3).
13 Perform fuel flow test (TM 9-2350-311-20-1).
NOT E
FOLLOW-ON MAINTENANCE:
Install electric fuel pump and hanger assembly
(TM9-2350-311-20-1)
5-9