5-1 ELECTRIC FUEL PUMPS — CONTINUED
b. Inspection and Repair — Continued
4
5
6
7
8
9
10
11
12
13
14
15
Perform fuel flow test (TM 9-2350-311 -20-1 ). Replace pumps if not within performance specifications.
Inspect shielded electrical cable (4). Replace if shorted, torn, or frayed.
Test electrical cable (4) for continuity (TM 9-2350-311 -20-1 ). Replace if damaged.
Inspect ground lead (22). Replace if tom, frayed, damaged, or defective.
Test ground lead (22) for continuity (TM 9-2350-311 -20-1 ). Replace if shorted.
Inspect cover assembly (5). Replace if damaged or deteriorated.
Test cover assembly (5) for continuity between terminal and terminal plate (10) (TM 9-2350-311-20-1).
Inspect hanger assembly (21 ). Replace if damaged.
Inspect pump hanger discharge fitting (3). Replace if damaged or defective.
Test operation of check valve (1) (TM 9-2350-311-20-1), Replace if defective.
Inspect hose (17). Replace if cracked or deteriorated.
Inspect all other components for damage. Replace if damaged.
5-6