5-13
TM 9-2350-311-34-2
1
Push cannon assembly (1) out of battery approximately 24 inches (61 cm) (TM 9-2350-311-20-2) and
place fabricated breech stand (2) beneath breech ring body (3).
2 Drain all hydraulic fluid from equilibration system (TM 9-2350-311-20-2).
3 Remove and discard cotter pin (4).
4 While holding shaft collar (5) with pipe wrench, remove slotted nut (6) from recuperator piston shouldered
shaft (7).