TM 9-2350-311-34-2
5
Apply hydraulic pressure to PRESSURE port (16) increasing from 0-3300 psi (0-22754 kPa). Valve (3)
should open at 3200 ± 100 psi (22064 + 690 kPa). Opening of valve is indicated by flow from RET port (15).
6
Remove lockwire (1).
7
Loosen outer nut (2) by turning counterclockwise.
8
To increase opening pressure, rotate adjusting screw (17) clockwise with a hex key. To decrease opening
pressure, rotate adjusting screw counterclockwise.
9
Tighten outer nut (2).
10
Measure valve (3) opening pressure (step 5). Repeat steps 6 through 10 as necessary until opening pres-
sure of 3200 ± 100 psi (22064 ± 690 kPa) is obtained.
11
When proper pressure setting is obtained, install new lockwire (1) to secure outer nut (2) to valve (3).
6-43