TM 9-2350-358-BD
5-5.
FUEL PUMP(S) (IN-TANK), INOPERATIVE-CONTINUED
Limitations:
None
Personnel/Time Required:
Right in-tank pump
•
3 soldiers
•
6.0 hours (includes 4.0 hours for removal/installation of powerpack)
Left in-tank pump
•
1 soldier
•
2.0 hours
Materials/Tools:
•
Fuel pump (scavenged from available source)
•
Rubber hose or strips (scavenged from available source)
References:
•
TM 9-2350-314-10
•
TM 9-2350-314-20-1-1
•
TM 9-2350-314-34-1
Procedural Steps:
1.
Drain fuel tanks.
2.
Gain access to the lower tank by removing powerpack (right in-tank pump) or engine compartment access cover
(left in-tank pump).
3.
Ensure that howitzer MASTER power switch is in the OFF position.
5-3