TM 9-2350-358-BD
5-6.
FUEL PUMP (MECHANICAL), INOPERATIVE - CONTINUED
WARNING
Do not smoke or use open flame when working on
fuel systems.
An explosion may occur, causing
serious injury or death.
2.
Disconnect fuel line to fuel pump.
3.
Remove fuel pump from governor housing.
4.
Remove fittings from fuel pump and install on replacement fuel pump.
5.
Install replacement fuel pump.
6.
Connect fuel lines to fuel pump.
7.
Record the BDAR action taken.
When the mission is complete, as soon as practical, repair the equipment/system
using standard maintenance procedures.
5-5