TM 9-2350-358-BD
11-12. HYDRAULIC HIGH-PRESSURE TUBING REPAIR (PERMASWAGING) - CONTINUED
8.
Slide permaswage fitting(s) all the way on the undamaged tube ends.
9.
Position replacement section between cut ends of undamaged tubing and slide permaswage fittings over gaps
between tube ends.
10.
Make sure insertion marks are visible on either side of the fitting.
Also, rotate fitting and replacement section until
long-axis marking align with marking on the undamaged tube end.
NOTE
For replacements requiring an end fitting, swage end fitting to replacement section first, as
described in step 11.
Then secure nut of the end fitting finger tight to the adapter.
11.
Position the permaswage tool one side the fitting and swage.
Then swage the other side of the fitting.
12.
Repeat steps 8 and 9 on the other end of the replacement section.
13.
Record the BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system
using standard maintenance procedures.
11-20