TM-9-2350-358-BD

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A6

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT SUPPORT MAINTENANCE

MARCH 1994

  TM-9-2350-358-BD - Page 244 of 343

TM 9-2350-358-BD
11-13. HYDRAULIC TUBE AND HOSE ISOLATION - CONTINUED
References:
TM 9-2350-314-20-2-2
Procedural Steps:
1.
Wrap tape around area to be cut.
Squarely cut end of hose and remove loose particles.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing.
To avoid Injury or death, keep away from open fire and use it in well-
ventilated area.
If adhesive, solvent, or sealing compound gets on skin or clothing, wash
immediately with soap and water.
2
Coat threads of long hexagon head bolt with sealing compound.
3
Install long hexagon head bolt inside hose.
4
Secure with two hose clamps.
Position clamp screws 180 degrees to each other.
5
Record the BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system
using standard maintenance procedures.
11-26


Back to Top