TM 9-2350-358-BD
11-13. HYDRAULIC TUBE AND HOSE ISOLATION - CONTINUED
2.
Remove adapter from bulkhead and supply hose.
WARNING
Adhesives, solvents, and sealing compounds can bum easily, can give off harmful vapors, and are
harmful to skin and clothing.
To avoid Injury or death, keep away from open fire and use it in well-
ventilated area.
If adhesive, solvent, or sealing compound gets on skin or clothing, wash
immediately with soap and water.
3.
Coat threads of pipe with sealing compound.
4
Install pipe plug in supply hose from other side of bulkhead.
5
Record the BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system
using standard maintenance procedures.
Option 3:
High-pressure line repair (tube isolation) using cap.
Limitations:
None
Personnel/Time Required:
•
1 soldier
•
0.5-1.0 hour
Materials/Tools:
•
Tube pipe fitting kit (found in M2/3 generic BDR kit, Section III, Appendix C)
•
Sealing compound (found in M2/3 generic BDR kit, Section III, Appendix C)
References:
TM 9-2350-314-20-2-2
11-23