TM-9-2350-358-BD

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A6

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT SUPPORT MAINTENANCE

MARCH 1994

  TM-9-2350-358-BD - Page 66 of 343

TM 9-2350-358-BD
3-16.
CIRCUIT BREAKERS, DAMAGED - CONTINUED
Limitations:
Protection offered by circuit breaker is eliminated.
Personnel/Time Required:
1 soldier
0.2 hour
Materials/Tools:
Tape, insulation, electrical (item 63, Appendix C)
Procedural Steps:
1.
Turn off MASTER power switch.
2.
Remove wires from damaged circuit breaker.
NOTE
Use appropriate method of splicing, either for small wires (para 3-
10) or for heavy-duty cable (para 3-12).
3.
Splice wires together, bypassing circuit breaker.
4.
Insulate and secure wires with electrical tape.
5.
Record BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system using
standard maintenance procedures.
3-21


Back to Top