TM-9-2350-358-BD

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A6

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT SUPPORT MAINTENANCE

MARCH 1994

  TM-9-2350-358-BD - Page 60 of 343

TM 9-2350-358-BD
3-12.
HEAVY DUTY CABLES, BROKEN - CONTINUED
Procedural Steps:
1.
Turn off MASTER power switch.
2.
Cut and splice corresponding wires (para 3-10).
3.
Wrap insulating tape around first splice and leave hanging.
4.
Cut and splice next corresponding wire, approximately 1 inch from first splice.
5.
Wrap tape around second splice without breaking tape from first splice.
6.
Repeat steps 2-5 until all splices are complete.
7.
Record BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system using
standard maintenance procedures.
3-13.
SHIELDED CABLES, DAMAGED
Some high-voltage or high-current electrical circuits are shielded to prevent the circuit from inducing a current in a parallel
circuit.
The shield is connected to a ground which will stop current from escaping or entering the conductor from any
source other than its own circuit.
Shielded cables should be replaced.
Repairs are possible if replacement cables are not
available.
Splicing wires is a quick fix for damaged shielded wires.
Option 1
Limitations:
Radio Frequency Interference (RFI) may be induced.
Personnel/Time Required:
1 soldier
0.5 hour
Materials/Tools:
Solder, lead-tin alloy (item 58, Appendix C)
Tape, insulation, electrical (item 63, Appendix C)
Wire, fuze (item 79, Appendix C)
3-15


Back to Top