TM-9-2350-358-BD

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A6

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT SUPPORT MAINTENANCE

MARCH 1994

  TM-9-2350-358-BD - Page 61 of 343

TM 9-2350-358-BD
3-13.
SHIELDED CABLES, DAMAGED - CONTINUED
Procedural Steps:
1.
Cut back coaxial cable cover 3 inches from each wire end.
2.
Cut back woven shield and inner conductor insulation on one wire 2 inches from end.
3.
Unweave woven shield and remove inner conductor insulation 2 inches from end of other wire.
NOTE
If solder is not available, lay wires side by side and wrap with fuze wire as shown.
4.
Splice broken wire by twisting and soldering.
5.
Insulate splice with several layers of tape.
6.
Lay unwoven shield over insulated splice and make contact with woven shield on other side of splice.
7.
Cover entire splice with several layers of tape.
8.
Record BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system using
standard maintenance procedures.
Option 2
Limitations:
RFI (radio frequency interference) may be induced.
Personnel/Time Required:
1 soldier
0.5 hour
3-16


Back to Top