TM 9-2350-358-BD
3-9.
CONNECTOR PIN, BROKEN, DAMAGED, OR MISSING
Connector pins can be bypassed when broken, damaged, or missing.
Connect wire to both ends of the connection wires.
Option 1
Limitations:
None
Personnel/Time Required:
•
1 soldier
•
0.3 hour
Materials/Tools:
•
Tape, insulation, electrical (item 63, Appendix C)
•
Wire, electrical, 20 AWG (item 78, Appendix C)
Procedural Steps:
1.
Turn off MASTER power switch.
2.
Identify faulty connector pin and wire at both ends of connector.
NOTE
If connector is attached to shock-mounted equipment, the
wires should be long enough to ensure free movement of
the equipment on its shock mounts.
3.
Cut wires at both ends of connector.
4.
Strip both ends of electrical wire, 20 AWG.
5.
Connect electrical wire to both ends of wires, not connected to the faulty connector.
3-6