TM 9-2350-358-BD
3-8.
WIRING HARNESS, DAMAGED - CONTINUED
Procedural Steps:
1.
Turn off MASTER power switch.
2.
Identify connector pin at each end of harness.
NOTE
Leave 1 inch of wire on connector.
3.
Cut off both ends of defective wire.
4.
Strip 1 inch off both ends of electrical wire, 20 AWG.
5.
Thread wire along path of cable harness passing wire through clamps.
6.
Splice and tape wire at both ends.
7.
Tape wire securely to harness at intervals to provide protection from vibration or sagging.
8.
Record BDAR action taken.
When the mission is complete, as soon as practical, repair the equipment/system
using standard maintenance procedures.
3-5