TM-9-2520-270-34

HYDROMECHANICAL CROSSDRIVE, TRANSMISSION HMPT 500 AND TRANSMISSlON CONTAINER ASSEMBLY

TECHNICAL MANUAL; DIRECT AND GENERAL SUPPORT MAINTENANCE

NOVEMBER 1984

  TM-9-2520-270-34 - Page 475 of 933

TM 9-2520-270-34
59. WORKING ON RIGHT SIDE OF HOUS-
ING (2), INSTALL THREE PLUGS (1).
a. Using 3/8-inch hex key, install
three plugs (1) in housing (2).
WARNING
Water under pressure can
injure you and others. Stand
clear of housing. Always wear
goggles.
61. FLUSH HOUSING (2) WITH CLEAN
WATER AT 40-100 psi (263.8-659.5 kPa)
AND 200 gpm (757 Ipm) FOR
FIVE MINUTES.
62. INSTALL PRIORITY VALVE OPENING
COVER (4) IN TOP OF HOUSING (2).
a. Place cover (4) on housing (2).
b. Install two screws (5).
c. Hand tighten screws (5).
60. INSTALL TWO PLUGS (3).
a. Using 3/16-inch hex key, install
two plugs (3).
GO TO NEXT PAGE
4-161


Back to Top