44.
45.
FLUSH HOUSING (1) WITH CLEAN
WATER AT 40-100 psi (263.8-659.5 kPa)
AND 200 gpm (757 Ipm) FOR
FIVE MINUTES.
WORKING ON FRONT OF
HOUSING (1), INSTALL MAKE-UP
PUMP OUTLET COVER (2).
a. Place cover (2) on housing (1).
b. Install two screws (3).
c. Hand tighten screws (3).
46.
47.
WARNING
Water under pressure can
injure you and others. Stand
clear of housing. Always wear
goggles.
FLUSH HOUSING (1) WITH CLEAN
WATER AT 40-100 psi (263.8-659.5 kPa)
AND 200 gpm (757 Ipm) FOR
FIVE MINUTES.
WORKING ON BOTTOM OF
HOUSING (1), INSTALL REGULATOR
COVER (4)
a.
b.
c.
Place cover (4) in housing
Install two screws (5).
Hand tighten screws (5).
(1).