TM 9-2520-270-34
81. REMOVE COVER (1).
a. Remove two screws (2)
b. Remove cover (1).
82. ROTATE HOUSING (3) ON TIP-OVER
STAND TO DRAIN WATER FROM
PORTS AND CAVITIES.
85. INSPECT HOUSING (3) FOR
SCRATCHES ON FINISHED SUR-
FACES OR CRACKS IN HOUSING.
REPLACE HOUSING IF DAMAGED.
86. INSPECT ALL MAIN HOUSING
INSERTS. See page 2-5.
a. Repair inserts if damaged. See
task REPAIR MAIN HOUSING
INSERTS, page 4-150.
84
WARNING
Compressed air can injure
you and others. Do not aim air
at soldiers. Do not use more
pressure than 20 psi (207 kPa).
Always wear goggles.
USING FILTERED LOW PRESSURE
AIR, BLOW WATER OUT OF ALL
SCREW HOLES, OIL PORTS, AND
HOUSING CAVITIES,
IF GEAR (4) IS INSTALLED,
LUBRICATE ROLLER BEARINGS (5)
WITH TRANSMISSION OIL TO
REMOVE ANY WATER.
87. IF GEAR (4) WAS REMOVED,
INSTALL GEAR. See task REPLACE
INPUT IDLER SPUR GEAR ASSEMBLY,
page 4-45.
4-166
83.