48. WORKING ON TOP OF HOUSING (1),
INSTALL RELIEF COOLER BY-PASS
COVER (2).
a. Using 1-inch drive ratchet handle and
1 3/4-inch socket, install cover (2)
in housing (1).
50. WORKING ON TOP OF HOUS-
ING (1), INSTALL PLUG (4).
a. Using 1-inch drive ratchet handle and
2 1/8-inch socket, install plug (4)
in housing (1).
WARNING
Water under pressure can
injure you and others. Stand
clear of housing. Always wear
goggles.
51. FLUSH HOUSING (1) WITH CLEAN
WATER AT 40-100 psi (263.8 -659.5
kPa)
AND 200 gpm (757 Ipm ) FOR
FIVE MINUTES.
49. WORKING ON RIGHT SIDE OF
HOUSING (1), INSTALL PLUG (3).
a. Using 5/8-inch hex key, install
plug (3) in housing (1).
52. REMOVE PLUG (4).
a. Using 1-inch drive ratchet handle
and 2 1/8-inch socket, remove
plug (4) from housing (1).
GO TO NEXT PAGE