TM 9-2520-270-34
12.
12.1
CHECK DEPTH OF PUMP HOUSING
CAVITY (1).
a.
b.
Using depth gage measure
depth of cavity (1).
If measurement is greater than
1.003 inches (25.46 mm), go to
step 12.1. If not, go to step 13.
REPLACE HOUSING (2). RECORD
FAILURE ON DA FORM 2407 AND
RETURN DEFECTIVE HOUSING TO
DEPOT.
CAUTION
Keep eccentric ring and outer rotor together
when measuring thickness to prevent loss of
spring and vane.
Inner and outer rotors must stay a matched
set. Damage to equipment can occur.
14. CHECK GEAR ROTOR SET (7).
a. Using micrometer caliper set,
measure thickness of inner rotor (4)
and outer rotor (8).
b. Replace gear rotor set (7) if either
measurement is less than 0.998 inch
(25.35 mm) and go to step 15.
c. Using micrometer caliper set,
measure thickness of ring (9)
d. Replace gear rotor set (7) if
measurement is less than 0.985 inch
(25.02 mm).
13. DISASSEMBLE SHAFT (3).
a. Remove inner rotor (4).
b. Remove and discard woodruff key (5)
c. Using screwdriver, remove retaining
ring (6). Discard retaining ring.
GO TO NEXT PAGE
Change 2
4-477