CLEANING
WARNING
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only
with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result
in injury to personnel.
Clean parts with fuel oil and dry with compressed air.
END OF TASK
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Inspect all parts for damage and excessive wear and replace as necessary.
2.
Using a spring tester, check bypass spring (Figure 1, Item 3) load. At 1.02 inches (25.09 mm), minimum
compression load must be 13.5 pounds (6.12 Kg). Replace as necessary.
END OF TASK
ASSEMBLY
Install bypass valve (Figure 1, Item 4), spring (Figure 1, Item 3), retainer (Figure 1, Item 2), and
screw (Figure 1, Item 1) in adapter (Figure 1, Item 5). Tighten screw securely.
END OF TASK
FOLLOW ON TASK
1.
Install oil filter adaptor (models 5063-5393 and 5063-539L) (WP 0019).
2.
Install oil filter adaptor (model 5063-5392) (WP 0018).
3.
Install oil filter adaptor (model 5063-5299) (WP 0017).
END OF TASK
END OF WORK PACKAGE
TM 9-2815-205-24
0075
0075-3/blank