ADJUST
1.
Start engine and operate until coolant outlet temperature of 160–185°F (71.1–85.0°C) is attained.
2.
Place speed control lever (Figure 5, Item 22) in IDLE position.
FULL FUEL
POSITION
22
27
28
8
31
30
29
28
32
33
MAINT_419
Figure 5.
Maximum No-Load Speed Adjustment Locations.
NOTE
Model 5063-5299 requires an idle speed setting of 650–700 rpm. Models 5063-5392,
5063-5393 and 5063-539L are set at 600–650 rpm.
3.
Hold idle speed screw (Figure 6, Item 8) and loosen idle speed locknut (Figure 6, Item 7). Adjust engine idle
speed screw to obtain 15 rpm below recommended idle speed. Prevent idle speed screw from turning and
tighten idle speed locknut.
4.
Stop engine.
Buffer Screw
WARNING
Avoid contact with hot manifolds, pulleys, and other moving parts. Wear proper ear
protection when running engine. Failure to comply may result in injury to personnel.
1.
Start engine and operate until coolant outlet temperature is 165–185°F (71.1–85.0°C).
TM 9-2815-205-24
0100
0100-7