SUSTAINMENT MAINTENANCE
ENGINE PREPARATION FOR RUNNING
INITIAL SETUP:
Tools and Special Tools
Tool Kit, General Mechanic's
(WP 0104, Table 1, Item 113)
Shield, Turbocharger, Protective
(WP 0104, Table 1, Item 89)
Materials/Parts
Antifreeze (WP 0103, Table 1, Item 3)
Oil, Engine (WP 0103, Table 1, Item 27)
Oil, Fuel (WP 0103, Table 1, Item 30)
References
TB 9-2350-368-25
References (cont.)
WP 0052
WP 0053
WP 0054
CAUTION
Run engine in clean area when air intake ducting is removed. Dirt, dust, and particles in
unfiltered air can enter engine and damage parts or cause mechanical failure.
INSTALLATION
1.
Install engine on dynamometer or powerplant test stand. Refer to TB 9-2350-368-25.
WARNING
A protective shield must be installed on turbocharger inlet prior to running engine without
built-in inlet screen or air cleaners. The turbocharger creates a strong suction at high
engine speeds and can pull hands or clothing into spinning blades. Failure to comply may
result in injury to personnel.
NOTE
Do not overfill any fluid reservoir/tank. If a fluid starts to flow out of reservoir/tank, stop
immediately to avoid spillage. Immediately clean up spilled fluid before proceeding with any
task.
2.
Connect source of fuel supply and fuel return to engine. Fill fuel filters with clean grade DF-2 fuel oil.
3.
Connect same type of air cleaners used for engine when in vehicle.
TM 9-2815-205-24
0099
0099-1