TM 9-2815-205-34
h.
i.
j.
k.
1.
CAUTION
If crankcase pressure is exces-
sively high, this pressure may
exceed the capacity of ma-
nometer. To prevent blowing
liquid out of manometer, dis-
continue test if liquid level
approaches limits of manome-
ter scale by closing manometer
tube connector.
Start engine and operate at 2500 RPM, FULL
LOAD. Slowly open manometer tube
connector (1), connected to nonmetallic
tubing (6), while carefully observing liquid
level in manometer tube.
NOTE
. A manometer measurement is the sum of the displacements from zero of the two
columns of liquid. The value expressed is in inches of water.
For model 5063-5299, crankcase pressure must not exceed 0.9 inch of water at 2500
RPM, FULL LOAD.
For all except model 5063-5299, crankcase pressure must not exceed 3.0 inches of
water at 2500 RPM, FULL LOAD.
When manometer tube connector (1) has been opened one full turn,
manometer scale.
Stop engine by moving governor stop lever to NO FUEL position.
Disconnect hose (6) and remove coupling half (5).
read crankcase pressure on