TM 9-2815-210-34-2-2
FRAME 2
CAUTION
1.
Hook up
2.
Hook up
Flame heater fuel pump electrical system is negatively
grounded. Pin A is positive and pin B is negative. Do
not switch polarity of pump during checking or replace-
ment. Changing polarity will permanently damage pump.
24-volt battery (1) with rheostat (2) to fuel pump receptacle (3).
voltmeter (4) to fuel pump receptacle (3).
GO TO FRAME 3
4-543