TM 9-2815-210-34-2-2
FRAME 2
1.
2.
3.
4.
5.
6.
Open adjustable valve (1) and start fuel pump.
Keep valve (1) open until system is purged of air.
Close valve (1).
Turn rheostat (2) until voltmeter (3) reads 24 volts.
Pressure gage (4) should read 90 to 100 psi.
To set pressure, if necessary, loosen check valve locknut (5)’ with wrench.
Turn relief valve adjusting screw (6) with screwdriver until pressure gage
reads 90 to 100 psi.
Hold relief valve adjusting screw with screwdriver and
tighten check valve locknut with wrench.
END OF TASK
4-534