TM 9-2815-210-34-2-2
4-57. FUEL INJECTION PUMP DRIVE GEAR ACCESS COVER (ENGINES LD-465-1,
LD-465-1C, AND LDT-465-1C).
There are no special cleaning procedures needed. Refer to
cleaning procedures given in para 4-3.
b. Inspection and Repair.
FRAME 1
1.
2.
3.
Check that
other way.
Check that
other way.
new access
five nuts (1) are not stripped, crossthreaded or damaged in any
If nuts are damaged, get new ones.
access cover (2) is not cracked, bent, dented or damaged in any
Take out minor bends or dents.
If more repair is needed, get a
cover .
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame.
Keep a fire extinguisher nearby when
solvent is used.
Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
Check that access cover (2) has no nicks, burrs or
surface.
Take out minor nicks, burrs or scratches
crocus cloth dipped in dry cleaning solvent.
END OF TASK
scratches on gasket
with a fine mill file or
4-525