TM 9-2815-220-24
SMOKE GENERATOR WIRING HARNESSES (2DR) REPLACEMENT
(PN 12354467, 11672386)
0068 00
REMOVAL (Continued)
1. Remove dual solenoid smoke generator wiring harness (1).
a. Cut and remove tie wrap (2).
b. Remove screw (3) and lock washer (4) retaining smoke generator ground lead (5).
Discard lock washer.
c. Disconnect two electrical connectors (6) from smoke solenoid valves (7).
d. Disconnect electrical plug connector (8) at T connection of starter ground circuit.
8
6
2
7
3, 4
1
5
WP 0068 00-2