TM 9-2815-220-24
SMOKE GENERATOR WIRING HARNESSES (2DR) REPLACEMENT
(PN 12354467, 11672386)
0068 00
REMOVAL (Continued)
2. Remove single solenoid smoke generator wiring harness (9).
a. Disconnect electrical connector at solenoid (10).
b. Remove screw (11) and lock washer (12) retaining smoke solenoid ground wire (13).
Discard lock washer.
c. Cut and remove tie wraps (14).
d. Remove screws (15), lock washers (16), and loop clamps (17) retaining smoke generator
harness (9) along front of engine.
Discard lock washers.
11, 12
10
9
15, 16, 17
14
(Various
locations
along
harness)
13
WP 0068 00-3