TM 9-2920-225-34
NOTE
If end bell is damaged or is not within limits given in
tables 2-8 and 2-9, generator is nonrepairable.
1.
Check that drive end bell (1) is not cracked, bent or warped.
2.
Measure inside diameter of drive end bell (1) bearing bore ( 2).
NOTE
When working on models 5504AA and 5504AB, if any part
of drive assembly is damaged, generator is nonrepairable.
3.
Check that block holder ( 3), retaining ring (4), drive blocks (5), drive
shaft (6), and coupling cover ( 7) are not bent, broken cracked or warped.
GO TO FRAME 3
MODELS 5504AA AND 5504AB
MODEL 5300GP
TA 103675
Table 2-8. End Bell Housing (Models 5504AA and 5504AB) Wear Limits
Size and Fit
Index of New Parts Wear Limits
Number
Item /Point of Measurement (inches) (inches)
2
Inside diameter of drive end bell 2.0465 to 2.0468 None
bearing bore
Table 2-9. End Bell Housing (Model 5300GP) Wear Limits
Size
and Fit
Index of New Parts Wear Limits
Number
Item /Point of Measurement (inches) (inches)
2
Inside diameter of drive end bell 2.4407 to 2.4412 None
bearing bore