TM 9-2920-225-34
1.
2.
3.
4.
5.
6.
Check that bearing (1) is not damaged. Refer to TM 9-214. If bearing is
damaged, get a new one.
Using multimeter, check rotor (2) for grounds by touching one test probe
of multimeter to rotor shaft (3) and other test probe to one slipring (4).
Ohmmeter reading must be over 10,000 ohms. If it is not, generator is
nonrepairable.
Do step 2 again for other slipring (4).
Using multimeter, check resistance of sliprings (4) by touching ohmmeter
probes to each slipring. Resistance must be between 1.5 and 2.5 ohms.
If it is not, generator is nonrepairable.
Check slipring (4) runout. Refer to para 2-9e.
Check that rotor shaft (3) is straight. Refer to para 2-9e.
END OF TASK
test
TA 103676
2-178