TM 9-2920-225-34
b. Test Stand Base Setting.
FRAME 1
I
1.
Set MAIN POWER switch (1) to OFF position.
2.
Set DC AMMETER LOAD AND STARTER selector (2) to 500 amperes.
3.
Set DC AMMETER FIELD AND BATTERY selector (3) to 30 amperes.
4.
Set MILLIVOLT METER RANGE selector (4) to 9 volts.
5.
Set DC VOLTMETER RANGE selector (5) to 50 volts.
6.
Set DC VOLTMETER CIRCUIT selector (6) to RECT /GEN position.
7.
Turn TACHOMETER PULLEY CALIBRATION control (7) to the left.
8.
Set TACHOMETER CIRCUIT selector (8) to DIRECT DRIVE position.
GO TO FRAME 2