TM 9-2920-225-34
1.
Hook up special purpose cable (1) to generator connector (2) and hook up
each lead of special purpose cable to alternator terminal and binding post on
test stand as labeled.
2.
Hook up a bus bar (3) to GND terminal (4) and D terminal (5).
GO TO FRAME 2
STARTER
0
0
0
0
ALTERNATOR
GENERATOR
TA 10371 7
2-223