TM-9-2920-258-30-P

ALTERNATOR, 180 AMPERES, MODEL 5520AB

TECHNICAL MANUAL; DIRECT SUPPORT MAINTENANCE MANUAL

APRIL 1989

  TM-9-2920-258-30-P - Page 12 of 76

TM 9-2920-258-30&P
2-5
TROUBLESHOOTING PROCEDURES (cont.)
3 Place one multimeter lead on pin "F" and one multimeter lead on point "A" (stator
assembfy). Check for continuity. If circuit is open, repair or replace pin as
required.
Follow above procedure to check pin "D," and then pin "B."
4
Place one multimeter lead on pin "E” and one multimeter lead on pin "D.”
Check
for continuity. If the circuit is open, repair or replace pin "E” or “D” as required.
2-4


Back to Top