TM 9-6920-430-14
b.
Place the coolant reservoir in the fragmentation chamber IAW steps
b
through
l.
c.
Open the OUTLET SHUTOFF valve two complete turns CCW. Observe
OUTLET PRESSURE gauge indication.
d.
Slowly open the OUTLET BLEED valve CCW until you hear gas escap-
ing.
e.
After 10 seconds, close the OUTLET BLEED valve fully CW. Observe
OUTLET PRESSURE gauge indication.
Continue bleed-down procedure untl
the desired coolant reservoir pressure indication is obtained.
f.
Close OUTLET SHUTOFF valve by turning fully CW.
g.
Slowly open the OUTLET BLEED valve, by turning CCW to relieve
pressure in outlet flexible hose.
h.
Remove coolant reservoir from fragmentation chamber IAW steps
u
through
af.