6515-01-647-9673

ANALYZER,INTRAVENOUS INFUSION PU


6515-01-647-9673 (6515016479673, 016479673)
Part Number (1 listing): 2394759
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 9 Sep 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-01-647-9673 Submit RFQ
Manufacturer Part Number RNCC RNVC Manufacturer Name CAGE
2394759 3 - Design Control Reference 2 - Production Item FLUKE BIOMEDICAL   1JZH3       
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6515-01-647-9673 Submit RFQ
FSG FSC NIIN FIIG INC CRITICALITY TYPE OF ITEM MRC DEMIL HMIC EDC PMIC ADPEC DATE CREATED
65 6515 016479673 T133-F 47433 X 4 3 A N A 0 9 Sep 2015
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

016479673

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-01-647-9673

T133-F

Federal Item Identification Guide (FIIG_4065)

47433

Item Naming Code (INC_4080)

9 Sep 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6515-01-647-9673 Submit RFQ
MOE Rule Former MOE AMC AMSC NIMSC IMC IMC Activity AAC DSOR Collaborators Receivers Effective Date
ZB01 1 Sep 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6515-01-647-9673 Submit RFQ
RNFC RNCC RNVC DAC RNAAC RNSC RNJC SADC MSDS HCC Reference Number CAGE
4 3 2 E 9Z D 2394759   1JZH3  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6515-01-647-9673 Submit RFQ
Integrity Originating HMC LCL WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
ZB
Code Definitions

ZB

Originating Activity Code (ORIG_ACTY_CD_4210)


Belgium

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-01-647-9673 Submit RFQ
MRC Decoded Requirement Clear Text Reply
ACDC Current Type AC
AKYN Furnished Items And Quantity USERS MANUAL AND SOFTWARE (1); 20 ML PRIMING SYRINGE (1); LUERLOCK-3 WAY (ONE FOR EACH CHANNEL); 5-FT PLASTIC DRAIN LINE (1)
FREQ Frequency In Hertz 50.0 OR 60.0
CXCY Part Name Assigned By Controlling Agency IDA 4 PLUS THREE-CHANNEL INFUSION DEVICE ANALYZER
APCB Portability PORTABLE
ABKW Overall Height 11.90 INCHES NOMINAL
ABHP Overall Length 7.50 INCHES NOMINAL
ABMK Overall Width 7.20 INCHES NOMINAL
FEAT Special Features THE DEVICE MEASURES INSTANTANEOUS FLOW, AVERAGE FLOW, OCCLUSION PRESSURE, AND ANALYZES PATIENT-CONTROL ANALGESIA (PCA) UNITS; WEIGHT,11 POUNDS; OPERATING TEMPERATURE: 59 F TO 86 F; STORAGE TEMPERATURE: 32 F TO 104 F; DO NO LEAVE FOR MORE THAN 48 HOURS AT -4 F; DIMENSIONS: 7.5 IN L X 7.2 IN W X 11. IN H; SUPPLY VOLTAGE: AUTOSWITCHING 90 VAC TO 260 VAC; SUPPLY FREQUENCY: 50 HZ TO 60 HZ; SUPPLY POWER: < 30 VA; FUSE: 20 MM 250 V, 1 A (T) (SLOW BLOW); COMPATIBLE WITH VIRTUALLY ANY TYPE OF INFUSION DEVICE; BUILT-IN MEMORY TO SAVE TEST RESULTS FOR PRINTING OR DOWNLOADING TO COMPUTER
ALUE Universal Medical Device Nomenclature System Code 16720
ELEC Voltage In Volts 90.0 AND 260.0


Back to Top