MWO-5-2350-262-35-4

ARMORED COMBAT EARTHMOVER (ACE), M9

MODIFICATION WORK ORDER

  MWO-5-2350-262-35-4 - Page 101 of 207

MWO 5--2350--262--35--4
3--72
SECTION VII INSTALLATION OF FORWARD ACTUATORS PRESSURE
TRANSDUCERS T5 AND T6
3--15 INSTALLATION OF FORWARD RIGHT ACTUATOR #1 PRESSURE
TRANSDUCER T5
NOTE
Steps a and f below apply to Figure 3--48.
NOTE
Area where pressure transducer T5 will be installed can be accessed from bowl area and
from underneath vehicle. It is recommended that installation be accomplished from most
convenient position.
a.
Access port 3 (6) of forward right rotary actuator #1 (1).
b.
Tag and disconnect hydraulic hose (4) connected to port 3 (6) of forward right rotary actuator #1 (1). The
other end of this hydraulic hose connects to Port 3R of right forward manifold.
c.
Attach diagnostic tee adapter, 8--4XHX6G5TP, (5) to port 3 of forward right rotary actuator #1.
d.
Attach pressure transducer, 12496923, (2) and o--ring, MS28778--4, (3) to 90--degree port of diagnostic
tee adapter (5). This pressure transducer has been functionally designated as T5.
e.
Connect hydraulic hose removed in step b above to in--line port of diagnostic tee adapter (5) attached to
port 3 of forward right rotary actuator #1.
f.
Reinstall actuator right access plate in ejector bowl using four saved machine bolts per
TM 5--2350--262--20--1, Actuator Access Plates Replacement, or leave off for installation of electrical
wiring harness in Chapter 5.
Figure 3--48. Installation of Pressure Transducer T5


Back to Top