MWO-5-2350-262-35-4

ARMORED COMBAT EARTHMOVER (ACE), M9

MODIFICATION WORK ORDER

  MWO-5-2350-262-35-4 - Page 96 of 207

MWO 5--2350--262--35--4
3--67
SECTION IV INSTALLATION OF PRESSURE TRANSDUCER T12
NOTE
Steps a through e below apply to Figure 3--43.
a.
Trace line 11 hydraulic hose (1) from bottom of pressure switch (located between two modified hydraulic
filter assemblies in upper portion of bowl area) to suspension sprung/unsprung valve (5) next to DCV
bank (2).
b.
Disconnect end of line 11 hose (1) attached to suspension sprung/unsprung valve (5).
c.
Attach diagnostic tee adapter, 8--4XHX6G5TP, (6) to port (line 11) on suspension valve (5).
d.
Attach pressure transducer, 12496923, (3) and o--ring, MS28778--4, (4) to 90--degree port of diagnostic
tee adapter (6). This pressure transducer has been functionally designated as T12.
e.
Connect line 11 hydraulic hose (1) (previously removed from suspension valve in step b) to in--line port of
diagnostic tee adapter (6).
Figure 3--43. Installation of Pressure Transducer T12


Back to Top