MWO 5--2350--262--35--4
3--73
SECTION VII INSTALLATION OF FORWARD ACTUATORS PRESSURE
TRANSDUCERS T5 AND T6 -- CONTINUED
3--16 INSTALLATION OF FORWARD LEFT ACTUATOR #1 PRESSURE TRANSDUCER T6
NOTE
Steps a through f below apply to Figure 3--49.
NOTE
Area where pressure transducer T6 will be installed can be accessed from bowl area and
from underneath vehicle. It is recommended that installation be accomplished from most
convenient position.
a.
Access port 3 (2) of forward left rotary actuator #1 (1).
b.
Tag and disconnect hydraulic hose (4) connected to port 3 of forward left rotary actuator #1. The other
end of hydraulic hose connects to port 3L of left forward manifold.
c.
Attach diagnostic tee adapter, 8--4XHX6G5TP, (3) to port 3 of forward left rotary actuator #1.
d.
Attach pressure transducer, 12496923, (6) and o--ring, MS28778--4, (5) to 90--degree port of diagnostic
tee adapter (3). This pressure transducer has been functionally designated as T6.
e.
Connect hydraulic hose removed in step b above to in--line port of diagnostic tee adapter (3) attached to
port 3 of forward left actuator #1.
f.
Reinstall actuator left access plate in ejector bowl using four saved machine bolts per TM
5--2350--262--20--1, Actuator Access Plates Replacement, or leave off for installation of electrical wiring
harness in Chapter 5.
Figure 3--49. Installation of Pressure Transducer T6
3--73/(3--74 blank)