TB-9-2320-280-35-12

TECHNICAL BULLETIN

INSTALLATION INSTRUCTIONS FOR EPLRS NETWORK MANAGER VEHICLE WITH AMTECH TOP

OCTOBER 2006
CHANGE 1

  TB-9-2320-280-35-12 - Page 132 of 162

TB 9-2320-280-35-12
5-104
47-32.
Attach shrink tubing (35) and terminal lug (48) to SINCGARS power cables (49) and (50). Secure
cables (49) and (50) to terminal board hole (51) in terminal board (32) with existing screw (34).
47-33.
Attach shrink tubing (35) and terminal lug (48) to lower EPLRS power cables (52) and (53). Secure
cables (52) and (53) to terminal board hole (54) with existing screw (34).
47-34.
Attach shrink tubing (35) and terminal lug (48) to upper EPLRS power cables (55) and (57). Secure
cables (55) and (57) to terminal board hole (56) with existing screw (34).
47-35.
Attach shrink tubing (35) and terminal lug (48) to SINCGARS negative cables (58) and (59). Secure
cables (58) and (59) to terminal board hole (60) with existing screw (34).
47-36.
Attach shrink tubing (35) and terminal lug (48) to lower EPLRS negative cables (61) and (63).
Secure cables (61) and (63) to terminal board hole (62) with existing screw (34).
47-37.
Attach shrink tubing (35) and terminal lug (48) to upper EPLRS negative cables (65) and (66).
Secure cables (65) and (66) to terminal board hole (64) with existing screw (34).
32
48
34
35
49
50
51
58
59
60
62
63
64
65
66
61
52
53
54
55
56
57
Figure 5-144.
48. TERMINAL LUG – CRS-DY-1010 – QTY. 6


Back to Top