TB-9-2320-387-35-1

SINGLE CHANNEL GROUND AND AIRBORNE RADIO SYSTEM (SINCGARS) AN/VRC-88F, AN/VRC-89F, AN/VRC-90F, AN/VRC-91F, AN/VRC-92F

TECHNICAL BULLETIN; INSTALLATION INSTRUCTIONS

OCTOBER 2005

  TB-9-2320-387-35-1 - Page 81 of 92

5-53
TB 9-2320-387-35-1
Section XVI. PLGR POWER CABLE INSTALLATION
16-1.
Route PLGR power cable (2) from PLGR assembly (1) to B-beam (3).
Figure 5-69.
5. TERMINAL LUG – 7728780 – QTY. 1
7. SHRINK TUBING – MS23053/4-302-0 – QTY. A/R
11. TERMINAL LUG – 7728777 – QTY. 1
Figure 5-68.
16-2.
Attach shrink tubing (7) and terminal lugs (5) and (11) to PLGR power cable negative lead (10) and
PLGR power cable positive lead (8). (Refer to TM 9-2320-387-24 for terminal connector repair.)
16-3.
Attach PLGR power cable positive lead (8) to 24-volt terminal board stud (4) with existing nut (6).
16-4.
Attach PLGR power cable negative lead (10) to ground strap stud (12) with existing nut (9).
2. PLGR POWER CABLE – 9728558-10 – QTY. 1
8
9
6
5
7
10
11
7
12
4
~
13
2
1
2
Change 1


Back to Top