2-104
TB 9-2510-251-13
1
1
1
REAR SIDE
ARMOR PLATE
REAR CENTER
ARMOR PLATE
REAR SIDE
ARMOR PLATE
2-1.3
Installation of Air Conditioning Kit to M1025 and M1025A1 with GSIE Add-on-Armor
(Cont’d).
h. Prepare System for Use
Figure 2-155.
Rear Side Armor Plates
Figure 2-156.
Rear Center Armor Plate
(1)
Using foam (1) and duct tape, seal as many cab air leaks as possible.
(2)
Purge and charge air conditioning system (para 4-14).