2-41
TB 9-2510-251-13
HIDDEN
24
23
25
2-1.2
Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d).
a. Install Compressor (Cont’d)
WARNING
Solvent used to clean parts is potentially dangerous to personnel and property.
Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes.
Wear
goggles and rubber gloves to protect eyes and skin.
Wash exposed skin
thoroughly.
DO NOT smoke or use near open flame or excessive heat.
Failure to
observe this warning could result in severe injury or death to personnel.
NOTE
To achieve good electrical ground, make sure no paint is present under
ground cables, in threaded hole, or on mounting surface.
Figure 2-58.
Clamp and Fuel Vent Line
27
26
Figure 2-59.
Mounting Bracket and Ground Cables
28
(16)
Loosen clamp (23) attaching fuel vent line (24) to valve cover stud.
(17)
Bend fuel vent line slightly rearward to clear compressor mount bracket.
(18)
Clean mounting surface where mounting bracket mounts to engine with solvent
(item 10, Appendix D).
(19)
Lower mounting bracket (25) and compressor onto mounting location in front left side of
engine.
(20)
Secure ground cables (26) to mounting bracket (25) with original bolt (27) and
washers (28).