2-34
TB 9-2510-251-13
2-1.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
with GSIE Add-on-Armor (Cont’d).
g. Air Distribution Ducting (Cont’d)
(3)
Two-door vehicles only:
a. Cut off male end of 90° elbows so the elbows fit over the square outlets on the plastic
plenum.
b. Attach 90° elbows to plenum.
c.
When air delivery is acceptable, apply a generous quantity of PVC cement
(item 3, Appendix D) to the mating surfaces and secure with screws.
h. Prepare System for Use
1
1
1
REAR SIDE
ARMOR PLATE
REAR CENTER
ARMOR PLATE
REAR SIDE
ARMOR PLATE
Figure 2-46.
Rear Side Armor Plates
Figure 2-47.
Rear Center Armor Plate
(1)
Using foam (1) and duct tape, seal as many cab air leaks as possible.
(2)
Purge and charge air conditioning system (para 4-14).