Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
with GSIE Add-on-Armor (Cont’d).
d. Install Refrigerant Hoses (Cont’d)
17
18
16
19
Figure 2-38.
Drier Connection
(14)
Connect Drier.
a. Lubricate O-ring and install #6 male stainless tube (16) on drier outlet.
b. Lubricate O-ring and install #6 female 90° fitting (17) on drier inlet.
c.
Trim ends of #6 hose (18) to condenser and connect to inlet (female) fitting.
d. Trim ends of #6 hose (19) to evaporator and connect to outlet (male) fitting.
e. Tighten fittings.