TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 34 of 624

2-18
TB 9-2510-251-13
39
43
2-1.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
Figure 2-25.
Condenser Hose Hole (Two-Door)
Figure 2-26.
Hose Guard
(29) Two-door vehicles only:
a. Drill a 1.25 inch diameter hole (39) for condenser hose in transmission tunnel, near
driver side vertical condenser mount angle.
b. De-burr hole.
(30)
Position hose guard (40) in recessed channel of bed behind condenser hose hole.
(31)
Using hose guard (40) as a template, drill 1/4 inch diameter hole in bed.
(32)
From underneath vehicle, insert bolt (41) and washer (42) through hose guard (40) and
bed.
(33)
Secure with locknut (43).
41
42
40


Back to Top