2-1.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
with GSIE Add-on-Armor (Cont’d).
a. Install Compressor (Cont’d)
WARNING
Solvent used to clean parts is potentially dangerous to personnel and property.
Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes.
Wear
goggles and rubber gloves to protect eyes and skin.
Wash exposed skin
thoroughly.
DO NOT smoke or use near open flame or excessive heat.
Failure to
observe this warning could result in severe injury or death to personnel.
Figure 2-8.
Adjusting Arm Installation
(19)
Clean mounting surface where adjusting arm mounts to water pump housing with solvent
(item 10, Appendix D).
(20)
Secure adjusting arm (22) to water pump housing with bolt (23), lockwasher (24),
washer (25), and washer (26).
(21)
Adjust tension on belt (27).
Rotate compressor outboard until proper belt tension is
reached.