TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 35 of 624

2-19
TB 9-2510-251-13
2-1.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
CAUTION
When handling condenser assembly, avoid damaging fins on underside of condenser.
Failure to comply may cause damage to equipment.
44
51
46
50
47
45
53
48
52
49
Figure 2-27.
Condenser Assembly
(34)
Position condenser assembly (44) on condenser mount angles (45) and secure top hole
with bolt (46), flat washer (47), and locknut (48).
(35)
Rotate condenser assembly (44) to horizontal position.
(36)
Four-door vehicles only:
a. Secure condenser assembly (44) to condenser mount angles (45) four door hole (49)
with bolt (50), flat washer (51), and locknut (52).
(37) Two-door vehicles only:
a. Secure condenser assembly (44) to condenser mount angles (45) two-door hole (53)
with bolt (50), flat washer (51), and locknut (52).
(38)
Tighten all mounting hardware on condenser mounting and evaporator unit mounting.


Back to Top